Focus on customer made high quality power lithium battery and test equiment to very application.
The device adopts electric energy feedback technology, which has high energy-saving efficiency and low system heat generation, which can greatly reduce the heat emission, power consumption and use cost of the equipment.
Item |
Model |
PSN-5V100A |
|
1 |
Main Channel qty |
8 channels each cabinet. Can make 8/16/32/48 channels as per your request |
|
2 |
Channel action mode |
Fully independent |
|
3 |
Working Power Supply |
Three-phase 5 wire system AC380V±10%,50HZ |
|
4 |
Main channel working mode |
Charging: constant current charging CC, constant voltage charging CV, constant current constant voltage charging CCCV, constant current constant voltage conversion without impact during charging; Discharging: constant current discharge CD, constant power discharge CP, constant voltage discharge; static, stop. |
|
Main channel test termination condition |
Time, voltage, current, capacity, etc. |
||
5 |
Main channel voltage |
Charging voltage range |
0V-5V |
Discharge voltage range |
1.3V-5V(1.3V is the device port voltage) |
||
Accuracy |
±(0.05%RD+0.05%FS) |
||
Resolution |
0.1mV |
||
Main channel current |
Maximum output current |
±100A |
|
Minimum output current |
±150mA |
||
Accuracy |
±(0.05%RD+0.05%FS) |
||
Resolution |
0.1mA |
||
Current start response time |
≤20ms(≤ 10msOptional) |
||
time |
Resolution |
1000mS |
|
power |
Output Power |
Maximum power of single channel continuous operation: 300W |
|
stability |
±0.1%FS |
||
efficiency |
Highest charging efficiency |
75% |
|
Maximum discharge efficiency |
75% |
||
Feeder |
harmonic |
≤3% |
|
Power Factor |
≥0.99 |
||
Auxiliary channel parameter cutoff function |
The main channel step can be stopped or switched when the auxiliary channel signal reaches a certain condition. |
||
6 |
communication method |
The device uses RJ-45 network interface. |
|
7 |
control program |
1. Support power-off data protection, support power outage, manual stop, and continue testing from data files. |
|
Safety protection conditions can be set, including: voltage lower limit, voltage upper limit, current lower limit, current upper limit, voltage and current trends, and single-step protection settings are supported. |
|||
Auxiliary channel protection conditions can be set, and the parameters that can be set include: voltage upper limit, voltage lower limit, temperature upper limit, and temperature lower limit. |
|||
Cycles |
Maximum 9999 |
||
Nested loops |
Maximum 10 floors |
||
Step time range |
Support h, min, S formats |
||
data record |
Time ≥ 1000mS |
||
8 |
Data presentation method |
Circular List |
There are cycle number, charge/discharge capacity, charge/discharge energy, average charge/discharge voltage, etc. |
Process List |
There are program number, working mode, process time, capacity, energy, termination voltage, termination current, etc. |
||
Detailed list |
It records serial number, system time, cumulative time, voltage, current, energy, power, etc. |
||
9 |
cooling method |
Forced air cooling |
|
10 |
Security Level |
Meets EN60950 and GB4943 requirements. |
|
noise |
The noise level should be tested according to the IEC62040-3 method, and the noise level should be less than 75dBA. The sound level meter used should meet the requirements of Type I in IEC804, and the accuracy should be better than ±0.5dB. |
||
Protection level |
IP22 |
||
11 |
Software upgrade service |
The software is upgraded free of charge for life until the hardware becomes incompatible. |
|
12 |
failure rate |
≤1% |
The device adopts electric energy feedback technology, which has high energy-saving efficiency and low system heat generation, which can greatly reduce the heat emission, power consumption and use cost of the equipment;
• Three-phase balance technology (no neutral line) reduces the load on the power grid;
• Soft start function reduces the impact on the power grid;
• The equipment accuracy is better than 0.05%, the data recording time can reach 1000mS/time, and the stability is high;
• Single point independence, independent charging and discharging conditions can be set for each channel;
• It has complete input and output, software and hardware protection, reverse connection protection, power failure protection, and poor fixture contact protection;
• There is no impact current when the channel starts, and the constant current to constant voltage transitions seamlessly without any current surge;
• Multi-layer network integrated management, one computer can centrally control more than 1000 channels, and the large system supports remote monitoring;
• The DC internal resistance test process can be defined and set by itself, providing a high reliability basis for the battery cell grouping (customization is required);
• Channels can be freely connected in parallel as needed to achieve multiple uses of one machine;
• When the computer is abnormal, it supports offline operation at an appropriate time (need to be customized);
• Modular design concept, plug-in design of the box, easy to maintain;
• The output line adopts quick plug-in method for easy installation and maintenance;
• The battery end uses a gold-plated ejector clamp to press down to reduce heat and facilitate battery loading and unloading;
• The system control circuit adopts a digital circuit with a high-speed DSP digital signal processor with floating-point operation as the core
• Synchronous rectification technology is used to improve energy utilization efficiency and reduce hardware size
• Rich peripheral resources and high-speed digital computing processing capabilities enable it to meet the needs of data processing and system control
• The control variables to be detected are directly sent to the DSP through the I/O port for processing
• The hardware design of the system is simple and reliable;
• The modular design makes the system upgrade and maintenance more convenient
• The data is clear and comprehensive, real-time monitoring and uploading to the MES system (need to be customized);
• Data export method: Data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charge and discharge rate, charge and discharge curve, voltage, capacity, current-time characteristics, etc., and the curves can be imported into EXCEL.
• Curve type: X coordinate: total time, charge and discharge capacity, number of cycles, etc., can be set freely. Y coordinate: total voltage, current, capacity, monomer temperature, charge and discharge capacity, monomer voltage, etc., can be set freely.
• Software protection: power-off data protection, power-off suspension and connection, overvoltage and over-discharge protection, overcurrent and undercurrent protection, capacity protection, overtemperature protection, current fluctuation abnormal protection, charging voltage rise rate abnormal protection, discharge voltage drop rate abnormal protection.
• Hardware protection: battery reverse connection, overcurrent protection, overvoltage protection.
• Alarm function: The hardware has emergency cut-off switch, automatic shutdown after power failure, automatic load connection and disconnection, etc.
• Output line: four-wire connection mode, current line and voltage line are separated.
• Maintainability: modular structure, spare parts can be used for timely replacement and repair, free of charge during the warranty period.
major function
Ask help with our service people if you have any questions.
FAQ