Focus on customer made high quality power lithium battery and test equiment to very application.
The 160 Channel 5 Voltage 40A Energy saving Prismatic Lithium Battery cell auto Analyze grading machine is a high-tech device designed to analyze and grade lithium battery cells with efficiency and accuracy. Its 160-channel capacity and 5 voltage options make it suitable for large-scale production needs. The machine's energy-saving features, precise grading capability, and automated process make it an impressive choice for battery manufacturers looking to streamline their production process and ensure high-quality results.
Model | PSN37-0516040 |
Number Of Device Channels | 160 channels |
Overall Dimension | Width 1880mm× Depth 1008mm× Height 2033mm |
Color | White |
Jig Form | Electric clamp opening, enhanced flat head clamp |
Fixture Spacing | 81mm |
Support Battery Specifications | 1. Battery compatible length 90-210mm,2. Thickness 16-70mm,3. Height 80-230mm,4. Battery tabs 40-150mm |
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ |
Power Factor | 0.99 @220V AC, Fully loaded, power grid THDu≤2% |
Ac Current Distortion Rate | <5% @220V AC, Fully loaded, power grid THDu≤2% |
Power Consumption | ≤28 KW |
Charging Efficiency Of Whole Machine | Charge≥80%; discharge≥70% |
Work Environment | Indoors, temperature is 10-30℃ under air convection. |
Heat-Dissipating Method | Air cooling |
Voltage Testing Range |
DC 0~5V |
Battery Voltage Range |
Charge DC 0~4.5V;Discharge DC 4.5~2V |
Constant Voltage Range |
DC 2~4.5V |
Voltage Accuracy |
±(0.5% Reading+0.5% Full Degree) |
Voltage Resolution |
0.1mV |
Voltage Stability |
≤(±1mV) |
Current Range |
Charge DC100mA~ 40A;Discharge DC 100mA~40A |
Accuracy Of Current |
±(0.5% Reading+0.5% Full Degre) |
Current Steady Reading |
≤(±1mA) |
Control Mode |
Computer Control Equipment Work,whole cabinet control/single board startup/single point startup, with scanning system |
Communication Mode |
485 serial port communication (baud rate 57600)/TCP communication/chart |
Workflow Setting |
Up to 32 work steps and 256 cycles can be set, with the function of nested loops |
Charging Mode |
The function of nested loops |
Charge Cutoff Condition |
Constant, current, constant, voltage, -△V |
Discharge Mode |
Voltage, current, time, capacity |
Discharge Cutoff Condition |
Voltage, time, capacity |
Time Range |
0~ 30000 minutes/work step, time unit: min |
Time Accuracy |
≤±1%0 |
Sampling Tour Period |
1s-60s optional |
Product Display